C\ Gabiria nº 112-114-146 Pº Ventas
20305 Irún (Guipúzcoa) SPAIN
Tel.: +34 943 633 562 | Fax: +34 943 633 285
E-Mail: conatec@conatec.com
CONATECwww.conatec.com

CONATEC
C\ Gabiria nº 112-114-146
Pº Ventas 20305
Irún (Guipúzcoa) SPAIN
Tel.: +34 943 633 562
Fax: +34 943 633 285
E-Mail: conatec@conatec.com


Cookies

HC 7030

Humidity and temperature controller for conditioning chambers

Designed to be used in product preparation chambers before baking. It is suitable to store merchandise in a chamber under controlled conditions of temperature and humidity.

General Characteristics

  • Operation in AUT mode (automatic) in those chambers in which the equipment controls humidity and temperature.
  • Operation in ANY mode (manual) for those chambers in which only temperature is controlled and steam, which is produced externally, is injected in a manual or timed manner.
  • The equipment stores the desired temperature and humidity, optionally the control of the humidity generator, and all the parameters related with the operation.
  • Permanent display of the temperature and humidity readings of the chamber.
  • LED indicator of the heating status.
  • LED indicator of the humidity status.
  • Control of the temperature and humidity of the chamber.
  • Control of the water level in the tank.
  • Control the rotation of the turbine.
  • Detection and notification of operation breakdowns.

Electric

  • Power: 230VAC. +/-15%.
  • Consumption: 5VA.
  • Pt100 type temperature signal input.
  • Input of HR from the sensor provided by CONATEC.
  • Range of measurement between 20 and 95% de HR.
  • Input of the level of the tank by means of free electrodes.
  • One heating control output by a 1A/230VAC relay.
  • An output by 7A/230VAC relay to control the steam generator.
  • One steam injection valve control output by a 1A/230VAC relay.
  • An output by 1A/230VAC relay to control the water level in the steam generator.
  • An output by 3A/230VAC relay to control the turbine.
  • One oven lighting control output by means a 1A/230VAC relay.
  • An output by 1A/230VAC relay to control the breakdown alarm.
  • Operating temperature between 0 and 60ºC.
  • Relative humidity of operation between 0 and 80% without condensation.
  • EC standards.

Mechanical

  • Horizontal format 48x96mm.
  • Depth: 140mm.
  • 44x92mm anchored window.
  • Front protection once mounted IP54.
Attached archives:

We use our own and third party cookies, for the analysis of user navigation. If you continue browsing, we consider that you accept the use.
You can change the settings or get more information here.