C\ Gabiria nº 112-114-146 Pº Ventas
20305 Irún (Guipúzcoa) SPAIN
Tel.: +34 943 633 562 | Fax: +34 943 633 285
E-Mail: conatec@conatec.com
CONATECwww.conatec.com

CONATEC
C\ Gabiria nº 112-114-146
Pº Ventas 20305
Irún (Guipúzcoa) SPAIN
Tel.: +34 943 633 562
Fax: +34 943 633 285
E-Mail: conatec@conatec.com


Cookies

Thermocouple S

The range of use of the type S thermocouples (Pt-PtRh10%) is between 500º C and 1,600 ºC. Depending on the operating temperature, different thermocouple wire diameters are mounted, the most typical being 0.5 mm, 0.4 mm, 0.35 mm, 0.30 mm, 0.25 mm and 0.20 mm. The higher the operating temperature the more recommendable it is to use larger wire diameters. The usual assembly of these types of thermocouples corresponds to an exterior ceramic protection structure, single or double, with different types of ceramic depending on the application and the operating temperature, and an electric connection using a standardised connection head. In some cases the interior ceramic protection and the exterior metal protection are combined with high temperature-resistant steels.

1.-Head B with single ceramic protection
2.-Ceramic cover with plug
3.-Probe with double ceramic protection
4.-Thermocouple S with ceramic die
 

Nous utilisons des cookies et des tiers, pour l'analyse de la navigation des utilisateurs. Si vous continuer à naviguer, considérez que vous acceptez l'utilisation. Vous pouvez modifier les paramètres ou obtenir plus d'informations ici.